The high voltage wiring of Lifane Solano has a number of features of the installation. Because of a soft coat, it's hard to lock the wire properly. Therefore, intermittent sparing may occur. To install, do the following:
- We take off the old wires and unpack the new wires.

- Soap solution, WD-40 or spray for high voltage wires by lubricating wire near caps 1.
- With the help of tweeties, we pull the wire for contact 2 of the cap 5-7 cm.
- Pinpoint the contact to the conclusion of the candle and draw the cap to the closing of the candle well.
- Repeat the procedure for the second end of the wire to properly put it on the coil output.
- Wear the wires and put on the back brace.